WY · statewide rule · verified November 5, 2026

Wyoming septic setback requirements

In Wyoming, the septic tank must sit at least 50 ft and the drainfield at least 100 ft from a private well, the drainfield at least 10 ft from the house and 10 ft from the property line. Source: WY DEQ Water Quality Rules Ch. 25, §7, Table 4 ↗. Measure your lot below to see what clears and what does not.

Private well100 ftdrainfield · tank 50 ft
House / foundation10 ftdrainfield · tank 5 ft
Property line10 ftdrainfield
Surface water50 ftdrainfield

Free lot check

Test your measurements against Wyoming minimums

Enter the distances you measured or read off the site plan. Leave unknown ones blank. Nothing is uploaded.

Enter at least one distance.Each row turns green when it clears the statewide minimum and red when it falls short.
Run the full property screen with Wyoming rules →
Wyoming statewide minimum horizontal setbacks in feet (verified 2026-11-05)
Distance toSeptic tankDrainfield
Private well50 ft100 ft
House / foundation5 ft10 ft
Property line10 ft10 ft
Surface water50 ft50 ft

Rule notes

  • Foundation walls with drains need 25 ft from the absorption system.
  • Public supply wells need 100 ft from the tank and 200 ft from the absorption system.
  • Well setbacks include neighbouring wells; surface water includes seasonal and intermittent springs and streams.

Citation: WY DEQ Water Quality Rules Ch. 25, §7, Table 4 · Wyoming DEQ Chapter 25 minimum horizontal setbacks ↗ · Verified against the rule text on November 5, 2026. Spotted a change? Tell us.

Context

How Wyoming compares with other states

  • Septic tank → private well: 50 ft is equal to the 50 ft median of 30 tracked states. It matches CDC's 50-ft siting guidance.
  • Drainfield → private well: 100 ft is the largest required distance among the 31 states Dakiv tracks. It is stricter than CDC's 50-ft siting guidance.
  • Septic tank → house: 5 ft is the smallest minimum among the 30 states Dakiv tracks.
  • Drainfield → house: 10 ft is equal to the 10 ft median of 32 tracked states.
  • Septic tank → property line: 10 ft is the largest required distance among the 30 states Dakiv tracks.
  • Drainfield → property line: 10 ft is the largest required distance among the 32 states Dakiv tracks.
  • Septic tank → surface water: 50 ft is equal to the 50 ft median of 25 tracked states.
  • Drainfield → surface water: 50 ft is equal to the 50 ft median of 30 tracked states.

Before you rely on a number

The permit office has the last word.

These are statewide minimums transcribed from WY DEQ Water Quality Rules Ch. 25, §7, Table 4. Counties, health districts and local boards in Wyoming can require more, and special cases — public wells, shoreland, sensitive aquifers or larger flows — use other distances. Get the approved site plan or as-built for an existing system before you buy, build or add on.

Find who permits septic systems for your parcel.

Start with the state program listed in EPA's directory, then confirm the county or district office.

Open the Wyoming permit finder

EPA state program contact ↗

Quick answers

Wyoming septic setback questions

How far does a septic system have to be from a well in Wyoming?

Under WY DEQ Water Quality Rules Ch. 25, §7, Table 4, the septic tank must be at least 50 feet from a private well and the drainfield at least 100 feet. These are statewide minimums for a private drinking-water well; public wells and local health departments can require more. CDC's national siting guidance is 50 feet.

How close can a septic tank be to a house in Wyoming?

The statewide minimum distance to the house or foundation is 5 feet for the septic tank and 10 feet for the drainfield. Check the notes on this page for basement, crawl-space or footing-drain cases, which often need more room.

How close to the property line can a septic system be in Wyoming?

Wyoming's statewide rule sets 10 feet for the tank and 10 feet for the drainfield from the property line. Easements, neighbouring wells and local ordinances can push the system further in.

How far must a septic system be from a lake or stream in Wyoming?

The statewide minimum to surface water is 50 feet for the tank and 50 feet for the drainfield. Shoreland, watershed and drinking-water-supply areas often carry larger buffers.

Can my county require larger septic setbacks than Wyoming's state rule?

Yes. These are statewide minimums. County health departments, districts and local boards can adopt stricter distances, and the permit office that controls your parcel has the final say. Use the permit finder to reach it before you buy, build or add on.