UT ยท statewide rule ยท verified November 5, 2026

Utah septic setback requirements

In Utah, the septic tank must sit at least 50 ft and the drainfield at least 100 ft from a private well, the drainfield at least 5 ft from the house and 5 ft from the property line. Source: Utah Admin. Code R317-4-13, Table 2 โ†—. Measure your lot below to see what clears and what does not.

Private well100 ftdrainfield ยท tank 50 ft
House / foundation5 ftdrainfield
Property line5 ftdrainfield
Surface water100 ftdrainfield ยท tank 25 ft

Free lot check

Test your measurements against Utah minimums

Enter the distances you measured or read off the site plan. Leave unknown ones blank. Nothing is uploaded.

Enter at least one distance.Each row turns green when it clears the statewide minimum and red when it falls short.
Run the full property screen with Utah rules โ†’
Utah statewide minimum horizontal setbacks in feet (verified 2026-11-05)
Distance toSeptic tankDrainfield
Private well50 ft100 ft
House / foundation5 ft5 ft
Property line5 ft5 ft
Surface water25 ft100 ft

Rule notes

  • Absorption system to a grouted well is 100 ft; an ungrouted well or spring needs 200 ft.
  • Buildings with a foundation drain need 10 ft (tank) and 100 ft (absorption system); deep wall trenches and seepage pits need 20 ft from a foundation.
  • Surface water = lake, pond, reservoir or watercourse, measured from the high water line.

Citation: Utah Admin. Code R317-4-13, Table 2 ยท Utah R317-4-13, minimum separation distances โ†— ยท Verified against the rule text on November 5, 2026. Spotted a change? Tell us.

Context

How Utah compares with other states

  • Septic tank โ†’ private well: 50 ft is equal to the 50 ft median of 30 tracked states. It matches CDC's 50-ft siting guidance.
  • Drainfield โ†’ private well: 100 ft is the largest required distance among the 31 states Dakiv tracks. It is stricter than CDC's 50-ft siting guidance.
  • Septic tank โ†’ house: 5 ft is the smallest minimum among the 30 states Dakiv tracks.
  • Drainfield โ†’ house: 5 ft is the smallest minimum among the 32 states Dakiv tracks.
  • Septic tank โ†’ property line: 5 ft is below the 10 ft median of 30 tracked states.
  • Drainfield โ†’ property line: 5 ft is the smallest minimum among the 32 states Dakiv tracks.
  • Septic tank โ†’ surface water: 25 ft is below the 50 ft median of 25 tracked states.
  • Drainfield โ†’ surface water: 100 ft is the largest required distance among the 30 states Dakiv tracks.

Before you rely on a number

The permit office has the last word.

These are statewide minimums transcribed from Utah Admin. Code R317-4-13, Table 2. Counties, health districts and local boards in Utah can require more, and special cases โ€” public wells, shoreland, sensitive aquifers or larger flows โ€” use other distances. Get the approved site plan or as-built for an existing system before you buy, build or add on.

Find who permits septic systems for your parcel.

Start with the state program listed in EPA's directory, then confirm the county or district office.

Open the Utah permit finder

EPA state program contact โ†—

Quick answers

Utah septic setback questions

How far does a septic system have to be from a well in Utah?

Under Utah Admin. Code R317-4-13, Table 2, the septic tank must be at least 50 feet from a private well and the drainfield at least 100 feet. These are statewide minimums for a private drinking-water well; public wells and local health departments can require more. CDC's national siting guidance is 50 feet.

How close can a septic tank be to a house in Utah?

The statewide minimum distance to the house or foundation is 5 feet for the septic tank and 5 feet for the drainfield. Check the notes on this page for basement, crawl-space or footing-drain cases, which often need more room.

How close to the property line can a septic system be in Utah?

Utah's statewide rule sets 5 feet for the tank and 5 feet for the drainfield from the property line. Easements, neighbouring wells and local ordinances can push the system further in.

How far must a septic system be from a lake or stream in Utah?

The statewide minimum to surface water is 25 feet for the tank and 100 feet for the drainfield. Shoreland, watershed and drinking-water-supply areas often carry larger buffers.

Can my county require larger septic setbacks than Utah's state rule?

Yes. These are statewide minimums. County health departments, districts and local boards can adopt stricter distances, and the permit office that controls your parcel has the final say. Use the permit finder to reach it before you buy, build or add on.