TN ยท statewide rule ยท verified November 5, 2026
Tennessee septic setback requirements
In Tennessee, the septic tank must sit at least 50 ft and the drainfield at least 50 ft from a private well, the drainfield at least 10 ft from the house and 10 ft from the property line. Source: Tenn. Comp. R. & Regs. 0400-48-01-.11 โ. Measure your lot below to see what clears and what does not.
Free lot check
Test your measurements against Tennessee minimums
Enter the distances you measured or read off the site plan. Leave unknown ones blank. Nothing is uploaded.
| Distance to | Septic tank | Drainfield |
|---|---|---|
| Private well | 50 ft | 50 ft |
| House / foundation | 5 ft | 10 ft |
| Property line | 10 ft | 10 ft |
| Surface water | 15 ft | 25 ft |
Rule notes
- Water row = gullies, drainageways, sinkholes, streams and cut banks.
- Distances can be increased or decreased on a soil consultant's special investigation.
Citation: Tenn. Comp. R. & Regs. 0400-48-01-.11 ยท TDEC rule 0400-48-01-.11 โ ยท Verified against the rule text on November 5, 2026. Spotted a change? Tell us.
Context
How Tennessee compares with other states
- Septic tank โ private well: 50 ft is equal to the 50 ft median of 30 tracked states. It matches CDC's 50-ft siting guidance.
- Drainfield โ private well: 50 ft is the smallest minimum among the 31 states Dakiv tracks. It matches CDC's 50-ft siting guidance.
- Septic tank โ house: 5 ft is the smallest minimum among the 30 states Dakiv tracks.
- Drainfield โ house: 10 ft is equal to the 10 ft median of 32 tracked states.
- Septic tank โ property line: 10 ft is the largest required distance among the 30 states Dakiv tracks.
- Drainfield โ property line: 10 ft is the largest required distance among the 32 states Dakiv tracks.
- Septic tank โ surface water: 15 ft is below the 50 ft median of 25 tracked states.
- Drainfield โ surface water: 25 ft is below the 50 ft median of 30 tracked states.
Before you rely on a number
The permit office has the last word.
These are statewide minimums transcribed from Tenn. Comp. R. & Regs. 0400-48-01-.11. Counties, health districts and local boards in Tennessee can require more, and special cases โ public wells, shoreland, sensitive aquifers or larger flows โ use other distances. Get the approved site plan or as-built for an existing system before you buy, build or add on.
Start with the state program listed in EPA's directory, then confirm the county or district office.
Open the Tennessee permit finderQuick answers
Tennessee septic setback questions
How far does a septic system have to be from a well in Tennessee?
Under Tenn. Comp. R. & Regs. 0400-48-01-.11, the septic tank must be at least 50 feet from a private well and the drainfield at least 50 feet. These are statewide minimums for a private drinking-water well; public wells and local health departments can require more. CDC's national siting guidance is 50 feet.
How close can a septic tank be to a house in Tennessee?
The statewide minimum distance to the house or foundation is 5 feet for the septic tank and 10 feet for the drainfield. Check the notes on this page for basement, crawl-space or footing-drain cases, which often need more room.
How close to the property line can a septic system be in Tennessee?
Tennessee's statewide rule sets 10 feet for the tank and 10 feet for the drainfield from the property line. Easements, neighbouring wells and local ordinances can push the system further in.
How far must a septic system be from a lake or stream in Tennessee?
The statewide minimum to surface water is 15 feet for the tank and 25 feet for the drainfield. Shoreland, watershed and drinking-water-supply areas often carry larger buffers.
Can my county require larger septic setbacks than Tennessee's state rule?
Yes. These are statewide minimums. County health departments, districts and local boards can adopt stricter distances, and the permit office that controls your parcel has the final say. Use the permit finder to reach it before you buy, build or add on.