NY ยท statewide rule ยท verified November 5, 2026

New York septic setback requirements

In New York, the septic tank must sit at least 50 ft and the drainfield at least 100 ft from a private well, the drainfield at least 20 ft from the house and 10 ft from the property line. Source: 10 NYCRR Appendix 75-A.4, Table 2 โ†—. Measure your lot below to see what clears and what does not.

Private well100 ftdrainfield ยท tank 50 ft
House / foundation20 ftdrainfield ยท tank 10 ft
Property line10 ftdrainfield
Surface water100 ftdrainfield ยท tank 50 ft

Free lot check

Test your measurements against New York minimums

Enter the distances you measured or read off the site plan. Leave unknown ones blank. Nothing is uploaded.

Enter at least one distance.Each row turns green when it clears the statewide minimum and red when it falls short.
Run the full property screen with New York rules โ†’
New York statewide minimum horizontal setbacks in feet (verified 2026-11-05)
Distance toSeptic tankDrainfield
Private well50 ft100 ft
House / foundation10 ft20 ft
Property line10 ft10 ft
Surface water50 ft100 ft

Rule notes

  • An absorption field upgradient of a well and in the path of surface drainage to it must stay 200 ft away.
  • Well distances increase 50% where the aquifer enters the well less than 50 ft below grade; seepage pits need 150 ft from a well.
  • Surface water includes streams, lakes, watercourses and wetlands, measured from mean high water. Counties may be stricter.

Citation: 10 NYCRR Appendix 75-A.4, Table 2 ยท NYS Department of Health, 10 NYCRR Appendix 75-A โ†— ยท Verified against the rule text on November 5, 2026. Spotted a change? Tell us.

Context

How New York compares with other states

  • Septic tank โ†’ private well: 50 ft is equal to the 50 ft median of 30 tracked states. It matches CDC's 50-ft siting guidance.
  • Drainfield โ†’ private well: 100 ft is the largest required distance among the 31 states Dakiv tracks. It is stricter than CDC's 50-ft siting guidance.
  • Septic tank โ†’ house: 10 ft is the largest required distance among the 30 states Dakiv tracks.
  • Drainfield โ†’ house: 20 ft is above the 10 ft median of 32 tracked states.
  • Septic tank โ†’ property line: 10 ft is the largest required distance among the 30 states Dakiv tracks.
  • Drainfield โ†’ property line: 10 ft is the largest required distance among the 32 states Dakiv tracks.
  • Septic tank โ†’ surface water: 50 ft is equal to the 50 ft median of 25 tracked states.
  • Drainfield โ†’ surface water: 100 ft is the largest required distance among the 30 states Dakiv tracks.

Before you rely on a number

The permit office has the last word.

These are statewide minimums transcribed from 10 NYCRR Appendix 75-A.4, Table 2. Counties, health districts and local boards in New York can require more, and special cases โ€” public wells, shoreland, sensitive aquifers or larger flows โ€” use other distances. Get the approved site plan or as-built for an existing system before you buy, build or add on.

Find who permits septic systems for your parcel.

Start with the state program listed in EPA's directory, then confirm the county or district office.

Open the New York permit finder

EPA state program contact โ†—

Quick answers

New York septic setback questions

How far does a septic system have to be from a well in New York?

Under 10 NYCRR Appendix 75-A.4, Table 2, the septic tank must be at least 50 feet from a private well and the drainfield at least 100 feet. These are statewide minimums for a private drinking-water well; public wells and local health departments can require more. CDC's national siting guidance is 50 feet.

How close can a septic tank be to a house in New York?

The statewide minimum distance to the house or foundation is 10 feet for the septic tank and 20 feet for the drainfield. Check the notes on this page for basement, crawl-space or footing-drain cases, which often need more room.

How close to the property line can a septic system be in New York?

New York's statewide rule sets 10 feet for the tank and 10 feet for the drainfield from the property line. Easements, neighbouring wells and local ordinances can push the system further in.

How far must a septic system be from a lake or stream in New York?

The statewide minimum to surface water is 50 feet for the tank and 100 feet for the drainfield. Shoreland, watershed and drinking-water-supply areas often carry larger buffers.

Can my county require larger septic setbacks than New York's state rule?

Yes. These are statewide minimums. County health departments, districts and local boards can adopt stricter distances, and the permit office that controls your parcel has the final say. Use the permit finder to reach it before you buy, build or add on.